REHVA took part in the fifth edition of European Energy Efficiency Day, held in Brussels on 14 and 15 October 2026 and co-organised by the European Alliance to Save Energy (EU-ASE) and the European Commission’s Directorate-General for Energy (DG ENER). Launched by EU-ASE in 2019, the initiative brings EU institutions, industry, civil society and technical experts together around Europe’s energy efficiency agenda, and this edition was framed explicitly as a moment of transition towards the post-2030 framework.

REHVA’s participation covered three strands of the programme: the gala dinner at the European Parliament on 14 October, the high-level policy discussion on the morning of 15 October, and — as co-organiser — the joint eu.bac–REHVA workshop on building automation that afternoon.

Gala dinner, 14 October

REHVA Vice-President Johann Zirngibl and Senior Policy & Advocacy Officer Francesco Robimarga attended the European Energy Efficiency Day gala dinner at the European Parliament, which opened the two-day programme.

High-level policy discussion, 15 October

The central policy discussion ran at the European Parliament from 9:00 to 13:30. It was opened by Monica Frassoni, President of EU-ASE, and Margareta Djordjevic, Head of the Energy Efficiency: Policy and Financing Unit (ENER.B.2) at DG ENER, with welcome addresses by Annalisa Corrado MEP and Niels Flemming Hansen MEP.

The first panel, Energy System Efficiency: A Driver of Affordability, European Competitiveness and Energy Security, moderated by Margareta Djordjevic, examined how efficiency gains across the whole energy system — production, grids, buildings, industry and transport — lower costs for citizens and businesses, reduce exposure to volatile energy prices and import dependence, and increase system resilience, with the discussion also placed in a global perspective ahead of COP31. Industry inputs came from ABB, Siemens Smart Infrastructure and Xylem, followed by reactions from Nicolas Casares MEP, Annalisa Corrado MEP and Niels Fuglsang MEP.

The second panel, Energy Efficiency Post-2030: Shaping the Next European Energy Framework, moderated by Monica Frassoni, assessed how energy efficiency must evolve within future EU climate, energy and industrial policy, and what is required for it to remain a central and enabling pillar of long-term decarbonisation, competitiveness and security. Dan Jørgensen, European Commissioner for Energy and Housing, delivered the keynote address, followed by reactions from Niels Flemming Hansen MEP, Pierfrancesco Maran MEP, chair of the Committee on the Environment, Climate Change and Food Security, and Mechthild Wörsdörfer, Deputy Director-General of DG ENER.

Johann Zirngibl and Francesco Robimarga represented REHVA in the discussion and in the group photograph with Commissioner Jørgensen.

Joint eu.bac–REHVA workshop: Building Automation for Better Performance — Delivering the EPBD in a Changing Climate

In the afternoon, REHVA co-organised with eu.bac a closed-format workshop at the European Parliament bringing together national and regional policymakers, European institution representatives, industry and technical experts. The session was moderated by Gusts Kossovics (eu.bac) and opened by Mārtiņš Staķis MEP and Bogdan Atanasiu of DG ENER, with Lin Liljefors also representing DG ENER. Each topic was introduced by short opening contributions and then discussed openly among all participants.

REHVA was represented by President Livio Mazzarella, Vice-President Johann Zirngibl and Senior Policy & Advocacy Officer Francesco Robimarga, joined by Luca Alberto Piterà, Secretary General of AiCARR, REHVA’s Italian member association.

The workshop worked through three questions in sequence.

Implementation challenges under Article 13. Because system requirements apply when technical building systems are installed, replaced or upgraded, the scope reaches, in principle, the whole building stock — and at each of those moments a qualified professional is involved. REHVA’s contribution placed the emphasis accordingly on professional training and on the information professionals pass to owners, supported by the one-stop shops for the energy performance of buildings foreseen under Article 18, which are intended to give households streamlined technical and financial guidance. On the qualifier that requirements apply in so far as this is technically, economically and functionally feasible, REHVA identified functional feasibility as the weakest of the three: it is defined only in the Commission guidance document, in terms general enough to leave real uncertainty, and the illustrative cases — a “significant loss of usability”, for instance — are not quantified. More broadly, REHVA pointed to the grey zones that directives leave at transposition, and to the absence of the detailed technical documents professionals need to act on them. European standards address part of this; practical guidebooks and simple-to-use tools, ideally built on a calculation kernel developed and maintained at European level, are needed alongside them.

Practical routes for compliance, verification and support. Article 13(10) sets out the required capabilities — continuous monitoring, logging, analysis and adjustment of energy use; benchmarking and detection of efficiency losses; communication with technical building systems; and indoor environmental quality monitoring, applicable from 29 May 2026 — but leaves room for interpretation as to how each is demonstrated. REHVA noted a terminological problem that has to be resolved before evidence requirements can be settled: “functionalities” carries one meaning in Article 13(10), where it concerns control and monitoring systems, and another in Annex IV in relation to the Smart Readiness Indicator, where it covers the building and its technical systems together. On verification, the Annex V energy performance certificate template requires an indication of whether a building can react to external signals and adjust its energy consumption — which implies that installers should hand over the relevant technical characteristics at the point of installation, for use when certificates are drawn up. The SRI records which functionalities are implemented, though not whether they operate as intended. What practitioners need, REHVA argued, is clear product information on building automation functionality together with a documented procedure setting out the steps of a compliance check; CEN standards have begun to incorporate compliance-check chapters, and CEN/TR 18276:2026, Checklist of compliance of building automation with EPBD requirements, published by CEN/TC 247 in February 2026, is a direct response to that need. A further avenue identified for cooperation between eu.bac, REHVA and industry is linking building automation functions to the EPB standards, so that designers and energy auditors can verify energy and CO₂ savings by reference to standardised functions.

Resilient buildings and the post-2030 agenda. On protecting comfort during heatwaves while containing energy demand, REHVA’s position is that there is no one-size-fits-all solution, and the association’s Resilient Cooling Design Guidelines (REHVA Guidebook No 33) sets out the design approach; Articles 7(6) and 8(3) require Member States to address climate change adaptation and indoor environmental quality, and the conditions to be achieved need to be defined, building on the tables in the Commission guidance. Technically, the route runs through holistic design and integrated whole-building control with an optimiser. For the next framework, REHVA’s priorities are a coordinated European implementation that avoids twenty-seven divergent transpositions — through European product and system standards and recognised European professional guidebooks — continuous cooperation between building authorities and professional stakeholders, and a trained, skilled and qualified workforce. On responsibility over time, the discussion distinguished legal responsibility, which rests with the owner or tenant according to the rental contract, from responsibility for actually delivering performance, which is best placed with building professionals or building management companies under performance contracts.

Next steps

The organisers agreed to prepare a short practical implementation note drawing together the findings of the workshop. REHVA thanks eu.bac for the invitation to co-organise the session, and EU-ASE and DG ENER for hosting European Energy Efficiency Day.