Cogeneration
is defined as the simultaneous generation of thermal and electrical energy in
one process. The technological implementations of this concept are known as
combined heat and power (CHP) systems. Cogeneration can be applied to different
scales, from large centralized plants to buildings. Decentralized cogeneration
systems installed in buildings are gaining an increasing interest and reaching
wide diffusion, aiming to produce electricity and heat near end-users, meeting
the demand for heating, hot water, while providing electricity to replace or
supplement the grid supply. This concept is called “micro-cogeneration”
(micro-CHP), defined as the local combined production of heat and electricity
with an electric output lower than 50 kWel according to Directive
2004/8/EC. Micro-CHP can be applied to different kinds of end-users, from
private dwellings to public and commercial buildings. In the residential
sector, electrical capacities are typically up to 5 kWel and heat
capacities up to 20 kWth, while in public and SME buildings, the ranges
are 5–50 kWel electrical and up to 250 kWth thermal [1].
Three are the main micro-CHP technology types currently available: internal combustion engines (ICEs), external combustion cycles – Stirling engines, Organic Rankine Cycles (ORC) – and fuel cells (PEMFC and SOFCs). The large majority of commercial micro-CHP units currently installed are based on ICEs, Stirling engines and ORCs. The ratio between electrical and thermal generation varies between technologies, with lower ratios for combustion devices, thus better suited to large buildings with high heating loads, while fuel cell systems can reach electrical efficiencies up to 60% [2], being thus fit for self-consumption schemes of auto-generated electricity.
Micro-CHP
systems are in the early phase of commercialization. In 2015, worldwide
micro-CHP sales accounted to 270 000 units, with 15% of units
installed in Europe and the remaining part mostly in Japan [3].
The main
advantage of micro-CHP is that allows achieving a larger primary energy
efficiency – above 80% [4] – compared to the separate production of heat and
electricity, thanks to the recovery of waste heat from the process. The
reduction in primary energy use due to higher efficiency results in the
reduction of greenhouse gas (GHG) emissions, even if CHPs are not a
zero-emission solution, because the vast majority are fuelled by natural gas.
The increase in energy efficiency also results in lower operating costs for the
users. On the user side, another advantage relies in the capability of
micro-CHP systems to help transform consumers into energy 'prosumers' (i.e.
producers and consumers), putting them at the core of future energy systems.
From the point of view of the global European energy system, micro-CHP can also
provide all the advantages of distributed electricity generation: help the grid
stability by generating electricity close to consumption at times of need and
improve the security of electricity supply. On top of that, micro-CHP diffusion
has an economic impact, creating and safeguarding jobs [3].

Figure 1. Benefits of micro-cogeneration in the building sector [3].
Besides
the aforementioned benefits, there are still some drawbacks or barriers
hindering the wide adoption of micro-CHP units in the building sector. The most
important are: the high first-capital cost, the lack or limited financial
support to ensure a suitable payback period and sometimes administrative
hurdles, such as authorization to electric grid connection. On top of that,
local micro-CHP generation based on combustion technologies brings about
environmental concerns regarding local emissions (such as NOx, CO, SOx,
particulate matter, unburned hydrocarbons, etc.) [4]. The last drawback is
overcome by the fuel cell micro-generation, which has near-zero local emission
of pollutants because the core technology is not based on the combustion of
fuels.
Fuel
cell based micro-CHP systems could be a good candidate for the residential
sector. Almost all the FC-based micro-CHP installations worldwide are
considering FC systems of 0.5–1.5 kWel since most of the units are
operated at constant point without modulation (electrical power production is
sized to cover a “base load”, while peaks are supplied by the grid). The
authors have studied in previous works [5–7] the performance of high
temperature SOFC and low temperature PEMFC cogeneration systems under different
regulating strategies, configurations (heat pump, battery, etc.) and economic
scenarios.
The
first important launch of fuel cell based micro-CHP systems for residential use
took place in Japan with the Ene.Farm project. As of December 31st, 2018,
a total of 292 654 commercial Ene.Farm units has been deployed in Japan.
The Japanese government supported for a long period the Ene.Farm program, with
high initial subsidies, then gradually reduced as the industry matures and
costs come down until subsidy will be unnecessary. Figure 2 shows the trend of number of installations and costs from 2009 to 2017
in Japan. Investment cost for a FC-CHP system decreased from 24 900 €
to 9 400 € (costs are referred to a typical size of 0.7–1 kW).

Figure 2.
Locations of micro-CHP units demonstrated as of November 2016.
Europe
has followed the Japanese initiative by financing fuel cell based micro-CHP
installations in the framework of two projects, called Ene.field and PACE,
financed by the private-public platform Fuel Cell and Hydrogen Joint
Undertaking. Furthermore, a dedicated national program in Germany (KfW433) has
helped the widespread use of the technology. According to the last available
data from 2019, about 10 000 fuel cell micro-CHP systems have been
deployed in Europe [8].
The
Ene.field project (European-wide field trials for residential fuel cell
micro-CHP, 2011–2017) has demonstrated more than 1 000 small stationary
fuel cell systems (1046 units: 603 SOFC and 443 PEMFC) for residential and
commercial applications in 10 countries, installing a total capacity of
approximately 1 155 kW of distributed power generation. Among the
installed units, more than 5.5 million hours of operation have been reached in
total, with more than 4.5 million kWh electricity produced. Figure 3 shows a map of the Ene.field project installations across Europe.
Germany
has been the most successful market for Ene.field in terms of deployment
numbers, with more than 750 units installed here. Funding from the national
support schemes helps decrease the investment costs, and therefore favours the
ramping up of the installation numbers. Moreover, high electricity prices make
the technology more attractive in Germany than in other European countries [9].

Figure 3.
Locations of micro-CHP units demonstrated in the Ene.Field project.
Real-life data from the field trial shows average electrical efficiencies of 37% for the SOFC systems and 32% for the PEMFC systems. Average thermal efficiencies are 46% for SOFC and 57% for PEMFC. It is important to mention that these are average values within all the systems installed and standard deviations are very high (for electrical efficiency, st. dev. is 30–59% for the SOFC and 48–66% for the PEMFC).
The
second step of the European fuel cell based micro-CHP diffusion has been the
ongoing PACE project (Pathway to a Competitive European FC mCHP market, 2016–2021).
The project is on track to achieve its target of installing 2 800
fuel cell micro-CHP units in households across Europe by 2021. As of January
2019, more than 1 200 fuel cell units have been sold, nearly half of the
project’s target number. Last year saw significant increases in sales in
several countries, with exponential growth in Belgium thanks to a favourable
investment climate [10].
The only
country where specific subsidies for fuel cell systems are available is
Germany, where the Cogeneration Act was passed in 2002 and revised several
times, most recently in January 2016. Here the fuel cell market appears to be
in transition, somewhere between the pilot phase and market diffusion [2,11].
The programme [12] provides a grant between 7 050 and 28 200 €
per fuel cell – depending on the electrical output of the fuel cell system –
for installation in new or existing buildings, and for residential and non-residential
buildings. Fuel cell are subsidized in the power range from 0.25 to 5.0 kW
electrical power. The economic support could include the investment cost for
the fuel cell system and its installation, the cost of the full maintenance
contract in the first 10 years and the costs for the services of the energy
efficiency expert.
A
CHP-based Feed-in-Tariff was also available in the United Kingdom but was
stopped in March 2019. Italy also has a cogeneration systems
dedicated supporting scheme, which includes a relatively low price paid for the
electricity produced and a reduction on the taxes paid on the natural gas fed
to the system. Anyway, both the UK and IT supporting schemes were referred to
generic micro-cogeneration systems and not specifically to fuel cell, as
happening in the German case.
When discussing about opportunities for FC micro-CHP systems, the residential building sector is not the only accessible market. Non-residential building sector includes all the commercial activities and office buildings. This market is addressed in the framework of a dedicated European project, ComSos (Commercial-scale SOFC systems, 2018–2020). The project aims to validate and demonstrate fuel cell based combined heat and power solutions in the mid-sized power ranges of 10–60 kW, referred to as Mini FC-CHP. ComSos goal is the installation of 20–25 units in the mid-size power range, from 3 European producers (Convion Oy, SOLIDpower SPA and Sunfire GMBH). Unlike the PACE and Ene.field initiative, ComSos focuses only on SOFC systems, because of the superior advantages of the technology among the competitors (high efficiency and zero emissions). A dedicated market analysis was developed to define the best business cases for the installation of the SOFC system. Some results are presented below.
The main
criteria for the selection of the best suitable market for the SOFC-CHP
installation are the availability of a base load – essential to run the SOFC at
a near-constant power output through the lifetime – and optimal energy prices
(electricity price higher than NG price). The spark spread, defined - in this
framework - as the difference between the electricity and natural gas prices
(in €/kWh), is one of the key elements which is influencing the economic
sustainability of the fuel cell installation (without any specific supporting
scheme).
Supermarkets
have been found as the best candidates for the installation of the FC-CHP
system. For medium-large size supermarkets, it is possible to define a quite
constant Energy Intensity in the range 600–800 kWh/m². A dedicated
modeling of the SOFC system coupled with a typical supermarket (with hourly
electrical and thermal profiles retrieved from [13]) has been developed in the
framework of the project. Figure 4 shows the results for a 60 kW
SOFC module installed in a supermarket in different countries (with different
consumption profiles depending on the location) in the hypothesis of a
subsidized scenario. The most striking, even if expected, finding is the direct
and strong correlation between the spark spread and the Relative Pay Back Time
(RPBT), defined as the time in which the SOFC investment starts to become
economically more convenient than the base scenario (electricity from the grid
and heat from a natural gas boiler). The correlation between the energy prices
difference and the economic performance of the investment is pointed out. Best
markets for the SOFC installation are Italy, the UK, Spain and some US cities.

Figure 4. Results of the analysis of FC system installation in supermarkets.
The status of fuel cell technology of the building sector worldwide is covered in the present work. Both landmark projects and supporting schemes are reviewed. The case of Japan shows how the diffusion of fuel cell based micro-CHP systems is feasible and that the optimal size for residential buildings lies in the range 0.4–0.7 kW electrical. In Europe, different EU-funded initiatives and German dedicated subsidies are pushing the market entry of these systems. The overall number of installed units in Europe still lacks behind the Asian numbers. However, results from demonstration projects gave credibility to the whole fuel cell sector showcasing the high performance of this concept and underlined criticalities on which producers should focus (cost reduction and improved lifetime). Increased sales should be encouraged by subsidies to improve the near-term economics of micro-CHP units, and may be crucial for the technology to reach the mass market and hence for the EU to harvest the anticipated environmental and system benefits, while creating new jobs.
On November 19th 2019, industry and stakeholders from the energy sector launched the Joint Declaration on Stationary Fuel Cells for Green Buildings to draw attention to the tremendous potential of stationary fuel cells to decarbonise the buildings sector. The signatories acknowledge that households and small businesses will play a vital role in the energy transition. With heating and cooling in buildings responsible for 36% of carbon emissions in Europe, they call for action to reduce our carbon footprint in the buildings sector with efficient, renewable and decentralised smart energy solutions.
[1] Energy matters. Micro-CHP potential
analysis: European level report. CODE2 report, 2015.
[2] I. Staffell et al., “The role of hydrogen and fuel cells in the global energy system,” Energy Environ. Sci, vol. 12, p. 463, 2019.
[3] The Benefits of Micro-CHP: A Delta-ee report produced on behalf of COGEN Europe, 2015. http://www.cogeneurope.eu/medialibrary/2015/05/19/d6648069/miro-CHP%20study_merged.pdf
[4] Sibilio, Sergio, and Antonio Rosato. "Energy technologies for building supply systems: MCHP." Energy Performance of Buildings. Springer, Cham, 2016. 291–318.
[5] M. Gandiglio, A. Lanzini, M. Santarelli, and P. Leone, “Design and optimization of a proton exchange membrane fuel cell CHP system for residential use,” Energy & Build., vol. 69, pp. 381–393, 2014.
[6] R. Napoli, M. Gandiglio, A. Lanzini, and M. Santarelli, “Techno-economic analysis of PEMFC and SOFC micro-CHP fuel cell systems for the residential sector,” Energy & Build., vol. 103, pp. 131–146, 2015.
[7] M. Sorace, M. Gandiglio, and M. Santarelli, “Modeling and techno-economic analysis of the integration of a FC-based micro-CHP system for residential application with a heat pump,” Energy, vol. 120, pp. 262–275, 2017.
[8] “FCW Exclusive: Tokyo Fuel Cell Expo 2019 - 300,000 Ene-Farms - FuelCellsWorks.” [Online]. Available:https://fuelcellsworks.com/news/fcw-exclusive-tokyo-fuel-cell-expo-2019-300000-ene-farms/. [Accessed: 10-Jan-2020].
[9] E. R. Nielsen et al., “Status on Demonstration of Fuel Cell Based Micro-CHP Units in Europe,” p. fuce.201800189, Jul. 2019.
[10] “PACE on track for 2800 micro-cogen units installed by 2021,” Fuel Cells Bull., vol. 2019, no. 3, p. 5, Mar. 2019.
[11] J. von Geibler et al., “Identifying business opportunities for green innovations: A quantitative foundation for accelerated micro-fuel cell diffusion in residential buildings,” Energy Reports, vol. 4, pp. 226–242, Nov. 2018.
[12] “Energieeffizient Bauen und Sanieren - Zuschuss Brennstoffzelle (433).” [Online]. Available: https://www.kfw.de/inlandsfoerderung/Privatpersonen/Bestandsimmobilie/Förderprodukte/Energieeffizient-Bauen-und-Sanieren-Zuschuss-Brennstoffzelle-(433)/. [Accessed: 10-Jan-2020].
[13] U.S. Department of Energy, “Commercial and Residential Hourly Load Profiles for all TMY3 Locations in the United States - Datasets - OpenEI DOE Open Data,” 2013. [Online]. Available: https://openei.org/doe-opendata/dataset/commercial-and-residential-hourly-load-profiles-for-all-tmy3-locations-in-the-united-states. [Accessed: 02-Apr-2019].