The EU
Horizon 2020 research project CoNZEBs (Solution sets
for the cost reduction of new Nearly Zero-Energy Buildings (NZEB) - 01/06/17 to
30/11/19), identify and assess technology solution sets that lead to
significant cost-reductions of new NZEBs in four EU member states (Denmark,
Germany, Italy and Slovenia). All solution sets have been assessed by life
cycle costs (LCC) analysis and life cycle environmental assessment (LCA)
providing a longer-term perspective than the construction costs. Some results
obtained are quite remarkable as they indicate that a balance point between
energy saving measures and renewable energy (solar) supply has been crossed. In
other words, the LCC and LCA analyses show that both for economic and
environmental reasons it pays off to reduce insulation levels and introduce
PV-systems and/or solar heating systems on NZEBs. Results from this work – primarily
for one of the countries – Denmark – is presented below.
In the project, solution sets have been developed, which are a combination of technologies, i.e. building fabric and technical building systems that together with ordinary building components constitute a building that meets the NZEB requirements.
Analyses of the solution sets was carried out using national tools for proving compliance with energy performance requirements.
The solution sets are for Denmark:
1. High efficiency insulation in exterior walls resulting in lower construction costs for foundations, window fittings and roofs.
2. Domestic hot water (DHW) solar heating; reduced insulation in walls, roof and floor.
3. Four-layer windows; water saving fixtures; natural ventilation (illegal as balanced mechanical ventilation is required in new multi-family houses); heat recovery on grey wastewater.
4. Reduced insulation in walls, roof and floor; decentral mechanical ventilation; efficient water fixtures.
5. Reduced insulation in walls, roof and floor; decentral mechanical ventilation; roof PV panels.
In the solutions sets shown above, decrease of the insulation level at the thermal envelope is one of the common features. This is natural when considering the resulting cost reductions that include lower costs for insulation material, lower costs for window installation, smaller facade area, smaller foundations and roof when maintaining the same habitable area.
In some countries, replacement of traditional heating systems with less costly ones are also among the solutions. In some cases, this is not legal due to national legislation that e.g. prohibits direct use of electricity for space heating.
In NZEBs, domestic hot water is one of the prime contributors to the building’s energy demand. Hence, in some solution sets, water saving fixtures or heat recovery on the grey wastewater have been used to reduce the energy demand for domestic hot water. This opens for use of less efficient/costly solutions elsewhere in the building and thus lowering the investment costs.
A summary of cost optimisation results from the Danish calculation are shown in Table 1.
Table 1. Summary of cost results from
analyses of solution sets. Building envelope is the average
U-value of the building fabric. GFA is gross floor area.
Danish
solution sets | ||||||
Typ.
NZEB | DK-1 | DK-2 | DK-3 | DK-4 | DK-5 | |
Building envelope [W/m²K] | 0.26 | 0.26 | 0.31 | 0.21 | 0.31 | 0.31 |
Energy costs(GFA) [€/(m²yr)] | 11.8 | 11.8 | 11.8 | 11.7 | 11.7 | 11.7 |
Investment costs(GFA) [€/m²] | 1247 | −2.1 | −5.5 | −18.1 | −15.0 | −12.6 |
All the identified solution sets are further assessed regarding cost savings using LCC and with respect to the environmental impact using LCA analysis, which both provide a long-term perspective than just the reduced investment costs. The results of the LCC and LCA are compared to those obtained for conventional minimum energy performance (min. EP) buildings, conventionally built NZEBs and buildings that go beyond the NZEB level – zero-energy or even plus-energy houses. For Denmark the beyond NZEB has been defined as a “0-energy building”, without including household electricity.
The LCC used for this analysis is resulting in the total net present value (NPV) of the technology solution sets over a fixed period of 30 years. The LCA calculations in this project cover two phases: Production and Use. Generally, the input values/parameters to use for the LCA calculation in both phases are available in each country. An overall decision has been made on how to handle the input to the two phases for each country. For this work, it was agreed to focus the results on two LCA parameters: Non-renewable primary energy (NR-PE) use and global warming potential (GWP), known as CO2-equivalent emissions. Both NR-PE factors and GWP emissions due to different energy supply options during the use phase have been analysed by each country.
The beyond NZEB, the Typical NZEB and the range of the results from the solution sets are compared to the min. EP building. The range of NZEB solution sets is interpreted as the interval between the best and the worst NZEB solution set result with respect to the LCC and LCA results obtained individually. The two improved technologies that constitute the difference between min. EP and typical NZEB building are the starting point to each alternative NZEB solution set. They are: 3-layer windows instead of 2-layer window and a mechanical ventilation system with good heat recovery, instead of one with average recovery. The results are presented in Figures 1-3 as differences compared to the min. EP building.
Figures 1-3 show that all the alternatives to the min. EP buildings are more environmental friendly, when comparing greenhouse gas emissions in the form of kg CO2-equiv./m² and non-renewable primary energy use to the min. EP building. However, from a purely economic perspective, only one of the solution sets and the beyond NZEB building are more cost-effective than the min. EP building. The beyond NZEB building is a more cost-efficient solution than the min. EP building, due to the economic value of larger energy savings than those of the NZEB.

Figure 1. GWP analysis for typical NZEB, range of NZEB solution sets and beyond NZEB in comparison with min. EP.

Figure 2. NR-PE energy analysis for typical NZEB, range of NZEB solution sets and beyond NZEB in comparison with min. EP.

Figure 3. NPV for the different improved energy performance levels compared to minimum EP – Denmark.
Investment cost reductions in the four countries range from 1 €/m² (with a slightly better energy performance) to 94 €/m², with the highest cost savings in an Italian solution set. Solution sets can obviously not be compared directly across climate zones and national legislation. However, it is envisaged that some solutions in another country's solution set may inspire to new combinations and hence new solution sets.
One of the main ideas of the CoNZEBs project was to investigate if LCC and LCA analyses conducted over a time-span of minimum 30 years would cast more light over what is the most cost-effective and environmental friendly building energy level – min. EP, NZEB or beyond NZEB.
The analyses are carried out for well-defined reference/typical multi-family buildings in each country (Figure 4) for each of the three energy use levels.

Figure 4. Illustration of typical multi-family houses used for the CoNZEBs solution set analyses in Denmark, Germany, Italy and Slovenia.
One of the
overall conclusions, based on the Danish results are: Typical NZEB is less
cost-effective than min EP, but beyond NZEB can be more cost-effective. Both
NZEB and beyond NZEB can be more environmentally friendly than min. EP. The
different solutions for NZEB reduce the CO2-equivalent
emissions by 31 to 43 kg/m² over a 30-year period. For the beyond NZEB,
the total number is 287 kg/m². This compare to the typical total CO2-equivalent emissions over a 30-year period of
a new conventional building in Denmark of 400-500 kg/m². Interesting is
also that several of the solutions sets show that the insulation levels can be
reduced by only adding a solar heating or PV system, or implementing energy
efficient water taps - in all cases showing improved GWP compared to the
typical NZEB. It needs to be said that reduction of insulation thicknesses are relatively small – about 50 mm – thus these reductions
does not compromise the indoor thermal comfort nor diminish the resilience and
passive habitability. One of the solutions sets even showing improved
cost-efficiency compared to the min. EP building.
So far, the
results for Denmark has reached the goal of pointing the way for optimum design
of new buildings in the future.
On the
project website (http://www.conzebs.eu) there are information about all
the results obtained in the project. Among them is a survey of users'
experiences and expectations of low-energy buildings, and a brochure on the
benefits of living in low-energy buildings.
CoNZEBs
is a EU Horizon 2020 project on the topic ‘Cost reduction of new Nearly
Zero-Energy buildings‘ (call H2020 EE 2016 CSA, topic
EE-13-2016). As such, it receives co-funding by the European Union under the
Grant Agreement No. 750046.
CoNZEBs project is a co-operation between four
different countries: Germany (Fraunhofer IBP & ABG-FH), Denmark (Kuben, BL
& SBi/AAU), Italy (ENEA & ACER RE) and
Slovenia (GI ZRMK & SSRS). The partners are from different research organisations and national housing organisations.
Fraunhofer IBP leads the project.
The
authors like to thank our colleagues for their involvement and commitment in
the project.