Jørn Toftum
Guest editor
Professor, Head of section DTU Sustain

 

From a Nordic perspective, harsh climates and high energy costs have guided building design towards highly insulated and airtight envelopes. While effective in reducing energy use, such designs may not always support occupant health and well-being or provide resilience to future climatic conditions. With contributions from both industry and academia, this issue of REHVA Journal presents Nordic trends in HVAC, ventilation, design, commissioning and operation of buildings, and new findings underlining the importance of indoor environments for occupant health and well-being.

To address high radon levels in soil and bedrock from a ventilation perspective, a new model has been proposed that estimates and controls indoor radon levels by providing the necessary ventilation rate in residential buildings (p.51). A study showed that overheating occurred in a large proportion of nearly 67,000 Swedish dwellings (p.30). Dwelling temperature affects sleep, which is essential to human health and well-being, but requirements for bedroom conditions are not specifically addressed in current standards and guidelines. A study recommends solutions to accommodate indoor environments in bedrooms for better sleep quality (p.13). This aligns well with an article describing how revisions to existing standards can help countries establish IEQ criteria for building design, energy performance, control, and assessment (p.5).

In a cleanroom, portable air cleaners can reduce ventilation requirements and annual energy use, while their effectiveness depends on airflow rate and placement (p.66). Other studies show how local air distribution has the potential to provide targeted protection for occupants in a patient room (p.62), and explains why breathing thermal manikins are important tools for evaluating the influence of ventilation systems on airborne infection risk (p.58).

Under particularly harsh arctic conditions in Greenland, mechanical ventilation with heat recovery is required for energy efficiency. A new inspection methodology aims to identify faults before they compromise system performance and occupants’ comfort and health (p.22). Occupant-related faults can be difficult to detect but data-driven approaches may be a solution to diagnose such faults (p.27). One study suggests continuous commissioning as a solution to improve the performance of demand-based ventilation systems (p.19), while another shows how a CFD digital twin at the design stage can de-risk the commissioning process (p.70). Nevertheless, while digitalization can improve the performance of building management systems there may also be serious risks of cyber-attacks that can jeopardize building operation (p.35).

Lowering district heating temperatures may improve efficiency, but in old apartment buildings it may challenge existing high-temperature radiator systems (p.47). Two studies focus on increasing the accuracy of building energy simulation models through representative occupancy profiles (p.44) and by synchronizing simulation output with building operation state in real time (p.39).

The studies included in this issue of REHVA Journal highlight the diversity of activities in the Nordic countries to improve building performance. We appreciate that REHVA offers this forum for exchange of information and hope that the articles will benefit the readers of the Journal.

Jørn ToftumPages - 4

Stay Informed

Follow us on social media accounts to stay up to date with REHVA actualities

0

0 product in cart.products in cart.