Keywords: openBEP4EU; EPBD; EPC; EN ISO 52000-1
|
|
|
|
|
Stavros Koltsios | Athanasios Kalamaris | Antonios Porfyrios Stratis | Georgios Giannakis | Laurent Socal |
EPB Centersk@epb.center | QUE Technologies | QUE Technologies | QUE Technologies | EPB Center |
The recast of the Energy Performance of Buildings Directive (EPBD, Directive (EU) 2024/1275) establishes the regulatory framework for assessing and certifying building energy performance across the European Union [1]. It requires Member States to anchor their national calculation methodologies on key European EPB standards [2], including the ISO 52000 family [3] and recommends the adoption of hourly or sub-hourly calculation intervals. This dynamic approach is essential for accurately representing building thermal dynamics and reflecting actual operating conditions.
Despite this harmonized regulatory ambition, a significant gap persists at the implementation level. First, national fragmentation remains high, as individual Member States diverge in their coverage of EPB standards and specific EPC indicator formulations, hindering cross-border market comparability. Second, from a software engineering perspective, the fragmentation of normative equations and computational rules across dozens of interrelated documents has led to various and often inconsistent, commercial software implementations.
The openBEP4EU project addresses these gaps by delivering the openBEP4EU calculation engine: an open-source, standards-compliant software implementation of the core EPB calculation procedures. The necessity for this implementation is driven by the following primary objectives:
· Bridging Standards and Software: It translates dispersed, complex normative documents into a transparent, executable and reproducible calculation core.
· Facilitating Comparability: By providing a universal reference engine, it establishes a common computational basis for generating EPC-relevant outputs, thereby increasing comparability, reliability and trust across different European regions.
· Enabling Quality Assurance: The engine can serve as a transparent benchmark for national certification schemes. Together with an evolving set of reproducible test cases, it enables practitioners, policymakers and financial institutions to perform rigorous quality assurance and comparability assessments of building energy performance results.
Developing the OpenBEP4EU Calculation Engine required a structured translation process combining conceptual mapping, programmability assessment and detailed variable traceability across multiple standards, primarily from the ISO 52000 family but also extending to other relevant standard families, including EN 16798 series, EN 15316 series, among others. This translation was not a purely mechanical conversion of equations into code; it also required careful interpretation of the logic, assumptions and intended application of the standards in an executable software environment. Furthermore, a distinguishing characteristic of the project is the close collaboration between the software developers and the experts (and authors of the standards) of the EPB Center, who are actively involved in the maintenance and evolution of the EPB standards. This interaction helps ensure that the software faithfully reflects the intent of the standards while simultaneously providing valuable feedback on practical implementation issues, ambiguities and opportunities for future improvements of the standards. In this way, software development and standardisation reinforce one another.
To establish a logical flow for the software architecture, the interrelated EPB standards were first organized into four sequential layers representing the physical and computational assessment chain of a building. As illustrated in Figure 1, the calculation progresses systematically:
· Input Layer: Gathers physical envelope characteristics (EN ISO 13370 [4], EN ISO 6946 [5]), climatic inputs (EN ISO 52010-1[6]) and operational schedules (EN 16798-1[7]).
· Energy Needs Layer: Calculates demand-side quantities, such as space heating and cooling (EN ISO 52016-1 [8]) and domestic hot water (DHW) needs (EN 12831-3 [9]).
· Technical Systems Layer: Converts these demands into delivered and exported energy use by modelling emission, distribution, storage and generation subsystems for heating, cooling, ventilation, DHW and lighting services.
· Output Layer: Aggregates system results into final performance indicators utilising the relevant national conversion (from EN ISO 52000-1 framework as well as aggregation options (Kexp).
Figure 1 presents the conceptual standards flow of the OpenBEP4EU Calculation Engine, showing how envelope, climate, product and operational inputs (Input layer) feed the energy-needs calculations (Energy Needs Layer), pass through service-specific technical system modules (Technical Systems Layer) and are finally aggregated through the EN ISO 52000-1 primary-energy conversion framework into EPC-relevant output indicators (Output Layer).

Figure 1. Conceptual standards flow guiding the development of the OpenBEP4EU EPB Engine.
For the entire set of examined standards, a detailed traceability analysis was conducted, decomposing each normative equation to trace interdependent variables back to their underlying user inputs. Furthermore, the development process followed a strict hierarchical sequence. Development began with the core Building Thermal Simulator (EN ISO 52016-1, ISO 52010-1, ISO 6946, ISO 13370, EN 16798-1), establishing the foundation for the hourly calculation of sensible and latent energy needs. Following validation of the demand-side solver, technical building systems for heating, cooling, ventilation, domestic hot water and lighting, together with renewable energy technologies, have been and continue to be progressively integrated.
Because of this planned, phased expansion, the current implementation and verification maturity across the framework is naturally non-uniform. Building envelope and thermal load modules are fully operational, while secondary ventilation and lighting systems are slated for upcoming releases. To transparently benchmark the strategic progress achieved so far, Figure 2 presents the current implementation and verification heat-map of the engine.

Figure 2. Heat map presenting the implementation and verification status of examined EPB standards.
The OpenBEP4EU calculation engine is designed around a highly modular, step-by-step data execution workflow. Rather than employing a rigid, monolithic solver, the engine separates the pure mathematical execution of the EPB standards from peripheral tasks such as data ingestion, validation and runtime control. This flexible workflow ensures that the system is easily maintainable, scalable and reusable by external software developers.
As illustrated in Figure 3, the complete pathway from raw data to final energy indicators is structured around five sequential operational phases, tightly managed by an underlying orchestration layer:
The complete path from data ingestion to output handling is structured around five primary component groups:
1. Data Import: The workflow initiates by acquiring building assets through two distinct routes. The engine natively ingests data structured according to the customized OpenBEP4EU JSON data model. Alternatively, to support openBIM methodologies, a dedicated import helper parses Industry Foundation Classes (IFC) files, automatically extracting geometric and material parameters and translating them into the internal JSON format.
2. Data Validation: Before any calculation occurs, the imported data passes through a strict validation gate. The engine tests the dataset against the formal criteria of the OpenBEP4EU JSON schema. This step verifies structural integrity, mandatory properties and data types, while performing semantic consistency checks to block malformed inputs before they reach the numerical core.
3. Data Transformation: Because the generalized JSON schema uses an object-oriented view of the building, the data must be prepared for numerical formulas. In this phase, module-specific helpers dissolve complex object relationships and map the validated data into precise variable dictionaries and arrays required by the standard-specific algorithms.
4. Building Performance Simulation Core: The simulation core comprises modular, domain-specific components implementing the standardized building performance calculation procedures. By decomposing the workflow into specialized modules rather than a monolithic solver, the architecture improves transparency, testability, validation, extensibility and third-party reuse, while allowing individual calculation domains to be refined or expanded without affecting the overall engine.
5. Building Performance Simulation Orchestration: The orchestration layer manages the overall calculation workflow, coordinating module execution, input preparation, dependencies, intermediate data exchange and output handling. By separating workflow control from domain-specific calculations, it preserves the modularity of the simulation core while enabling execution sequences, modules and output processes to evolve without modifying the underlying calculation methods.

Figure 3. Operational workflow and orchestration logic of the OpenBEP4EU Calculation Engine.
The preliminary assessment reported in Deliverable 2.2 “Advanced EU Kernel EPC Engine” [10] used a controlled sequence derived from BESTEST 600 [11]. A single lightweight residential zone in Athens was first simulated without active conditioning; the same model was then extended to a three-zone topology, before explicit split-system air conditioning was added (Figure 4). Results were checked against EPB reference spreadsheets where available and compared with EnergyPlus for trend and magnitude consistency [12].

Figure 4. 3D illustration of the single and multi-zone topologies.
Under free-floating operation, without heating or cooling intervention, the zone was solved hour-by-hour, allowing internal and operative temperatures to emerge solely from weather conditions, envelope heat transfer, ventilation, internal gains and solar gains. The presence of a south-oriented window resulted in pronounced daytime temperature increases in response to solar irradiance, with the largest temperature variations occurring during spring and summer. These results demonstrate the dynamic response of the thermal-needs core to fenestration and solar boundary conditions before any heating or cooling system is imposed.

Figure 5. Free-floating single-zone thermal response with south-oriented window.
The multizone test replicated the BESTEST 600-based zone to the east and north, with the northern zone window reoriented to reflect reduced solar exposure. Internal partitions were handled by replacing the external boundary temperature with the neighbouring zone air temperature from the previous timestep. Ideal loads then maintained operative temperature between the 20 °C heating and 26 °C cooling setpoints. Against the EPB spreadsheets, monthly needs matched very closely, with average deviations of 0.24% for heating and 0.27% for cooling, attributed mainly to rounding differences. EnergyPlus comparisons showed the same seasonal pattern and credible magnitudes: the south-facing zones behaved similarly, the north-facing zone had lower cooling demand and the centrally connected zone showed reduced heating demand.

Figure 6. Multizone heating and cooling needs compared with EnergyPlus for Athens.
For the multizone air-conditioning case, the ideal sensible needs were passed to three independent split units, one per thermal zone, linking each zone emitter to a dedicated generator.

Figure 7. Multizone implementation top-down view with A/C splits (left) and A/C splits heating-cooling characteristics (right).
The system layer converted heating and cooling needs into electricity using the heat pump capacity, COP/EER and degradation characteristics. The resulting monthly electricity profiles followed the needs-side trends: heating electricity appeared in winter, cooling electricity peaked in summer and zone-to-zone differences remained consistent with orientation and adjacency. The case therefore tested the full workflow from multizone thermal demand to delivered system energy.

Figure 8. Multizone split-system electricity consumption for heating and cooling.
The OpenBEP4EU Calculation Engine demonstrates that core EPB procedures can be translated from dispersed normative methods into a transparent, modular and executable software framework. The current release delivers an operational core covering hourly building thermal-zone needs and the modelling of various technical building systems, validated module-by-module against EPB reference spreadsheets and benchmarked against EnergyPlus for plausible trends and magnitudes. Future work will extend technical-system coverage to Renewable Energy Systems (RES), co-generation systems and lighting modules. The final open-source software release aims to provide a reusable reference framework to support quality assurance and improve comparability across European EPC implementations.
openBEP4EU is funded by the European Union's LIFE Programme under Grant Agreement No. 101167613. The views expressed are those of the authors and do not necessarily reflect those of the European Union or CINEA.
[1] Directive (EU) 2024/1275 on the energy performance of buildings (recast), especially Article 13 (technical building systems and BACS), Article 15 and Annex IV (SRI), Article 16 (data exchange), Articles 19-22 (EPCs and databases) and Article 23 (inspections). https://eur-lex.europa.eu/eli/dir/2024/1275/oj
[2] European Commission, Energy Performance of Buildings Directive - implementation information and EPB standards overview. https://energy.ec.europa.eu/topics/energy-efficiency/energy-performance-buildings/energy-performance-buildings-directive_en
[3] EN ISO 52000-1:2017, Energy performance of buildings — Overarching EPB assessment — Part 1: General framework and procedures. https://www.iso.org/standard/65601.html
[4] EN ISO 13370:2017, Thermal performance of buildings – Heat transfer via the ground – Calculation methods. https://www.iso.org/standard/65716.html
[5] EN ISO 6946:2017, Building components and building elements – Thermal resistance and thermal transmittance – Calculation methods. https://www.iso.org/standard/65708.html
[6] EN ISO 52010-1:2017, Energy performance of buildings – External climatic conditions – Part 1: Conversion of climatic data for energy calculations. https://www.iso.org/standard/65703.html
[7] EN 16798-1:2019, Energy performance of buildings – Ventilation for buildings – Part 1: Indoor environmental input parameters for design and assessment of energy performance of buildings.
[8] EN ISO 52016-1:2017, Energy performance of buildings – Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads – Part 1: Calculation procedures. https://www.iso.org/standard/65696.html
[9] EN 12831-3:2017, Energy performance of buildings – Method for calculation of the design heat load – Part 3: Domestic hot water systems heat load and characterization of needs.
[10] openBEP4EU Deliverable D2.2 – Advanced EU Kernel EPC Engine.
[11] ANSI/ASHRAE Standard 140 – Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs.
[12] EnergyPlus BESTEST Validation Report.