Francesco Mancini
Fabio Nardecchia
Daniele Groppi
Department of Planning, Design and Technology of Architecture, Sapienza University of Rome, Rome, Italy
francesco.mancini@uniroma1.it
Department of Astronautics, Electrical Energy Engineering, Sapienza University of Rome, Rome, Italy
fabio.nardecchia@uniroma1.it
Department of Economics, Engineering, Society and Business Organization, University of Tuscia, Viterbo, Italy
daniele.groppi@uniroma1.it

Francesco Ruperto
Carlo Romeo
Interdepartmental Centre for Landscape, Building, Conservation, Environment (CITERA), Sapienza University of Rome, Rome, Italy
f.ruperto@aliigo.it
Energy Efficiency Department (DUEE), Italian National Agency for Technologies, Energy and Sustainable Economic Development (ENEA), Rome, Italy
carlo.romeo@enea.it

 

 

Abstract: The energy refurbishment of the existing building heritage is one of the pillars of Italian energy policy. Aiming at energy efficiency and energy saving in end uses, there are wide and diversified improvement strategies, which include interventions on the building envelope and Heating, Ventilation, and Air Conditioning (HVAC) systems, with the introduction of renewable energy sources. The research focuses on the evaluation of energy consumptions and Indoor Environmental Quality (IEQ) in buildings, varying the airflow rates handled by the HVAC system. A Case Study (the Aula Magna of a university building) is analysed; an in-situ monitoring campaign was carried out to evaluate the trend of some environmental parameters that are considered to be significant. Additionally, dynamic simulations were carried out, aiming at evaluating the energy savings resulting from the airflow rates reduction. The outcomes of this case study highlight the opportunity to achieve significant energy savings, with only slight variations in IEQ; a 50% reduction in airflow rate would decrease energy consumption by up to 45.2%, while increasing the carbon dioxide concentration from 545 ppm to 655 ppm, while the Particulate Matter and Total Volatile Organic Compounds increase is insignificant.

Keywords: Indoor Environmental Quality; Indoor Air Quality; energy savings; dynamic simulation; monitoring campaign

Introduction

Nowadays, people spend a large part of their time (60–90%) inside buildings [1]; for this reason, the quality of confined spaces is a major concern for healthy indoor environments in Europe and it has a decisive impact on wellbeing of occupants [2] and their productivity [3]. The EE-TC-IAQ (Energy Efficiency-Thermal Comfort-Indoor Air Quality) dilemma represents a significant issue for building design and management [4,5]. Nevertheless, examples of an integrated approach are present, such as [6,7,8], in which attention was simultaneously paid to the reduction of energy consumptions ensuring satisfactory internal environmental conditions.

This paper focuses on energy efficiency measures applied to the HVAC system in a public university building. Such buildings have been demonstrated to have a significant energy savings potential [9]. University and scholastic buildings have, in fact, large energy consumptions and broad occupancy schedules, thus offering several opportunities for efficient refurbishment [10]. The aim of this research is to assess the link between energy consumptions and IEQ through the variation of the airflow rate that is handled by the HVAC system by means of an integrated and holistic approach that covers energy consumption and temperature, relative humidity, and IAQ optimization. Particularly, the research wants to demonstrate the possibility of strongly reducing the energy consumption without heavily affecting the IEQ by adopting a performance-based approach instead of the traditional prescriptive one.

The results of this study can be used to define ventilation strategies, in order to minimize energy consumptions while providing the required IEQ levels. The proposed methodology could be replicated to evaluate similar situations in other university buildings and more generally in buildings equipped with HVAC systems managed by advanced control systems.

Materials and Methods

The target of this work consists in the evaluation of building energy consumptions and IEQ, varying the outdoor airflow rates handled by the HVAC system. The study was carried out integrating two different methodological approaches, namely: i) a dynamic simulation has been carried out for the building energy performance assessment, while ii) an in-situ measurement campaign has been conducted to evaluate the IEQ. Furthermore, the results of the in-situ measurement campaign, in terms of indoor temperature, relative humidity, and electric loads, have been taken as reference for the dynamic model calibration and validation. Dynamic simulation has been used to evaluate the energy consumption as well as the indoor temperature and relative humidity variation in different scenarios.

Regarding the dynamic simulation model, the in-house developed code explained in detail in [11] has been adopted. The model allows to performe single-zone hourly dynamic simulations fully responding to the specific simulation needs of the case study consisting of a single large space.

Regarding the IEQ assessment, a detailed analysis of data was performed that had been gathered by means of in-situ experimental campaigns, during which indoor air temperature, relative humidity, and the concentration of some significant pollutants have been monitored, namely: CO2; PM10; and, TVOCs. The measured concentrations of indoor air pollutants have been compared to threshold values; the ranges of thresholds concentration may vary, depending on exposure times. In this study, were used the intervals shown in Table 1 [12], associating them with a synthetic qualitative classification.

Table 1. Measured pollutants: threshold values and classes.

Classes

CO[ppm]

TVOC [ppm]

PM10 [µg/m³]

Hazardous

1501 ÷ 5000

0.431 ÷ 3000

141 ÷ 750

Unhealthy

1001 ÷ 1500

0.262 ÷ 0.430

91 ÷ 140

Moderate

601 ÷ 1000

0.088 ÷ 0.261

31 ÷ 90

Good

340 ÷ 600

0.000 ÷ 0.087

0 ÷ 30

 

Regarding dynamic simulations, four different operating conditions of the HVAC system were simulated, as shown in Table 2. Regarding the measurement campaign, only two scenarios have been tested; this is due to the current possibilities offered by the HVAC system consisting of two AHUs. Thus, the measurements were carried out under two different operating conditions: (i) the two AHUs operating simultaneously (Scen. #0); and, (ii) a single AHU operating (Scen. #3).

Table 2. Summary of the analysed scenario.

Scenario

Relative Airflow Rate

Analysed Parameters

Dynamic Simulation

Measurement Campaign

Scen. #0

100%

Energy consumptions;

Thermal loads; T, RH

T; RH;

CO2, PM10, TVOC concentrations

Scen. #1

85%

Energy consumptions;

Thermal loads; T, RH

Scen. #2

70%

Energy consumptions;

Thermal loads; T, RH

Scen. #3

50%

Energy consumptions;

Thermal loads; T, RH

T; RH;

CO2, PM10, TVOC concentrations

 

Case Study Description

The analysed Case Study is the Aula Magna of Valle Giulia, headquarters of the Faculty of Architecture of the Sapienza University of Rome. It can be considered to be a relevant example for other highly crowded educational buildings, particularly for those buildings of historical heritage in which HVAC or mechanical ventilation systems were installed in a later stage. All the data regarding the building envelope and HVAC system were collected in order to characterise the building energy performance. An abacus of the existing vertical dispersing surfaces was created through non-destructive surveys. The direct wall thicknesses measurement allowed to characterize the stratigraphy of the wall structures; historical sources analysis allowed to reveal the absence of thermal insulation that became mandatory only after the construction of the building. The front walls are made of reinforced concrete masonry and have a thermal transmittance (U) of 1.16 W/m²K. The side walls are made of solid tuff masonry blocks with a U of 1.73 W/m²K. The external roof consists of a mixed slab with a U of 1.66 W/m²K. The floor towards the ground consists of a concrete slab positioned above pebbles and crushed stones; its U value is equal to 1.1 W/m²K.

Regarding the dynamic simulation, the following thermal loads were considered: (i) loads due to the presence of occupants (full room occupation: 50 W/m² [13]); (ii) loads due to the lighting system (LED lighting: 20 W/m², evaluated considering the actual lighting systems as fully radiative); loads due to electrical appliances (14 W/m²: evaluated considering the presence of 1 projector, 500 W, and 50 laptop 90 W each one).

In order to evaluate the seasonal and yearly energy consumptions, the weekly occupancy schedule was set as follows:

·         two days with morning lessons (occupancy 9 ÷ 12 a.m., HVAC system operation 8 ÷ 12 a.m.);

·         two days with afternoon lessons (occupancy 14 ÷ 17 p.m., HVAC system operation 13 ÷ 17 p.m.); and,

·         one conference day (occupancy 9 a.m. ÷ 17 p.m., HVAC system operation 8 a.m.÷ 17 p.m.).

The Aula Magna indoor temperature was set to comply with the standard comfort limits (winter 20°C, 50 % RH, summer 26°C, 50% RH). The Aula Magna is equipped with an external HVAC system, which processes airflow rate of 14,000 m³/h using two AHUs of 7,000 m³/h each. The AHUs consist of a classic configuration (pre-heating coil, adiabatic humidifier, cooling coil, and post-heating coil) and are equipped with a sensible heat recovery unit on the exhaust air.

Results and Discussion

Tables 3 and 4 summarize the results of the simulations carried out, respectively, for winter and summer operation, for each of the four simulated scenarios.

Table 3. Power and energy in winter operation for simulated scenarios.

 

Qheat,average

[kW]

Qheat,max

[kW]

Eheat,TOT

[kWh/y]

Pel,average

[kW]

Pel,max

[kW]

Eel,TOT

[kWh/y]

DEel,TOT

[%]

Scen. #0

64.46

131.49

36,741

16.87

43.25

9618

 

Scen. #1

55.19

112.51

29,417

14.53

37.00

7745

−19.5%

Scen. #2

45.44

93.39

23,176

11.94

30.78

6088

−36.7%

Scen. #3

33.22

71.92

15,315

8.64

24.77

3984

−58.6%

Table 4. Power and energy in summer operation for simulated scenarios.

 

Qcool,average

[kW]

Qcool,max

[kW]

Ecool,TOT

[kWh/y]

Pel,average

[kW]

Pel,max

[kW]

Eel,TOT

[kWh/y]

DEel,TOT

[%]

Scen. #0

96.92

178.84

34,817

20.95

48.11

7604

 

Scen. #1

85.38

166.34

32,186

18.57

44.71

7000

−7.9%

Scen. #2

75.47

153.85

29,282

16.36

41.31

6349

−16.5%

Scen. #3

62.18

137.19

25,306

13.39

36.77

5451

−28.3%

 

A comparison between the different scenarios shows a general reduction in energy consumptions, being higher during winter and lower during summer. Reducing airflow rate by 50% (scenario #3), during the winter season, energy savings of 58.6% were achieved, while lower savings (28.3%) were achieved during summer. On an annual basis, the savings reached 45.2% in scenario #3, 14.4% in scenario #1, and 27.8% in scenario #2.

Measurement Campaign―Summer Operation The measures were carried out in conjunction with events taking place in the Aula Magna, which provided relevant occupancy values throughout the day. Parallel to the thermo-hygrometric measurements, air quality measurements were carried out by detecting the concentrations of the selected pollutants (CO2, PM10, TVOC); Table 5 shows the results of the measurements.

Table 5. Measurement campaign results—summer operation.

Date

Occup.

T; RH [°C; %]

CO[ppm]

PM10 [mg/]

TVOC [ppm]

Out

In

In

Out

In

In

Out

In

In

Out

In

In

Sc. #0

Sc. #3

Sc. #0

Sc. #3

Sc. #0

Sc. #3

Sc. #0

Sc. #3

28/05/2018

250

24; 68.4

25.5; 50.3

26.1; 58.1

344

580

690

41.5

36.7

31.0

0.020

0.023

0.024

08/06/2018

270

27.2; 63

26; 48.9

26; 58.1

340

557

692

23.0

20.0

19.2

0.020

0.016

0.010

11/06/2018

250

28.5; 58.5

25.9; 50

26; 54.3

345

556

669

22.5

20.1

18.8

0.015

0.016

0.022

12/06/2018

250

28.3; 62.5

25.9; 50.7

26.1; 55.5

347

548

664

22.5

19.9

18.0

0.020

0.015

0.010

18/06/2018

300

28.5; 67.5

25.8; 50.1

25.9; 50.5

348

564

691

27.5

23.6

23.5

0.025

0.018

0.018

20/06/2018

250

29.6; 51.8

26; 50.1

25.9; 53.9

349

571

672

25.5

20.6

18.7

0.020

0.014

0.017

26/06/2018

300

28; 47.6

25.4; 49.8

26.1; 49.9

344

583

709

17.5

21.7

21.2

0.020

0.013

0.022

28/06/2018

270

27.2; 43.1

25.6; 48.9

25.9; 50.5

343

578

705

12.0

18.6

17.3

0.020

0.024

0.013

04/07/2018

250

30.3; 68.2

25.8; 49.2

25.9; 51.1

343

499

606

39.5

24.0

22.7

0.020

0.018

0.017

05/07/2018

230

29.8; 66.8

25.6; 48.9

25.9; 50.5

343

497

594

36.5

18.6

17.3

0.025

0.020

0.012

12/07/2018

200

29.2; 57

25.8; 48.9

25.9; 50.5

343

499

602

27.5

25.0

22.8

0.025

0.024

0.015

10/09/2018

250

25.3; 68.4

25.9; 50.7

25.9; 53.5

348

545

663

28.5

22.5

20.0

0.025

0.017

0.010

 

Regarding temperature and relative humidity measurements the HVAC system, operating at nominal flow (Scen. #0), revealed to be able to maintain the environmental parameters within the comfort range. Otherwise, when it operates with a halved flow rate (Scen. #3), the temperature control is still maintained while critical issues have been noted in controlling relative humidity, which tends to higher values sometimes exceeding the comfort range. Indeed, when the flow rate is halved, the system is able to guarantee the thermal power balance, since it does not need to compensate for the maximum sensible load during the tests. Nevertheless, when the flow rate was halved, the system was not always able to guarantee the needed balance of the latent heat. Simulation was used in order to check the maximum load condition (sensible and latent). The simulations confirmed that the system is always able to maintain temperature control, while, as the flow rate decreases, difficulties in controlling relative humidity become evident. With regard to the concentration of CO2, the value of the average concentration changes from 548 ppm (Scen. #0) to 663 ppm (Scen. #3), corresponding to a worsening of COindex level, which passes from the “good” to the “moderate” value. Regarding PM10 and TVOC concentration, there are minimal differences between the two monitored conditions, which remains in both situations “good”.

Measurement Campaign―Winter Operation The measurements related to winter operation, as shown in Table 6, were carried out with the same conditions as the ones used for summer operation.

Table 6. Measurement campaign results—winter operation.

Data

Occup.

T; RH [°C; %]

CO[ppm]

PM10 [mg/]

TVOC [ppm]

 

Out

In

In

Out

In

In

Out

In

In

Out

In

In

Sc. #0

Sc. #3

Sc. #0

Sc. #3

Sc. #0

Sc. #3

Sc. #0

Sc. #3

07/11/2018

250

14.8; 72

20.8; 50.8

20.8; 50.7

342

573

675

19.5

18.7

20.6

0.020

0.020

0.022

09/11/2018

280

14.7; 68.9

20.8; 50.6

20.8; 50.4

340

569

696

29.5

24.8

19.5

0.020

0.016

0.010

14/11/2018

240

12.1; 69.8

20.2; 50.4

20.4; 50.2

342

549

653

34.5

27.4

24.2

0.015

0.016

0.018

16/11/2018

300

12.6; 64.1

20.2; 50.2

20.5; 50.2

343

554

688

25.5

20.9

17.8

0.020

0.017

0.013

21/11/2018

200

12.9; 77.9

20; 50.6

20.5; 50.9

348

545

638

15.5

17.8

15.3

0.025

0.018

0.018

23/11/2018

220

14.9; 74.3

20.5; 50.1

20.5; 50.1

341

559

658

31.5

20.6

18.7

0.020

0.014

0.017

28/11/2018

280

8.1; 60.2

19.8; 50.1

20.4; 50.4

340

582

705

16.0

15.5

13.2

0.020

0.013

0.014

05/12/2018

300

10.8; 76.7

20.4; 49.6

20.4; 50.1

340

567

702

34.5

26.0

22.8

0.015

0.018

0.012

07/12/2018

250

10.1; 78.1

20.4; 49.3

20.5; 50.8

341

502

604

35.5

24.2

22.2

0.015

0.020

0.015

12/12/2018

270

4.9; 59.7

20.1; 50.1

20.5; 50.5

347

493

599

55.0

35.8

27.3

0.025

0.022

0.017

14/12/2018

180

7.2; 90

20.2; 50

20.4; 50.4

339

501

583

10.0

14.8

11.8

0.015

0.024

0.015

19/12/2018

270

6.9; 73.8

20.1; 50.5

20.3; 50.4

346

534

657

32.5

25.9

23.5

0.025

0.024

0.010

21/12/2018

160

9.8; 78.1

20.1; 49.9

20.4; 50.3

341

480

555

37.5

33.4

31.0

0.025

0.024

0.015

 

The HVAC system, operating at nominal flow (Scen. #3), is able to maintain the environmental parameters within the comfort range, which confirms what has already been seen for the summer season. However, there is an interesting difference with respect to the summer season; indeed, the HVAC system is able to maintain the environmental parameters within the comfort range, even in half-capacity operation during winter season. During winter, the Aula Magna was never fully occupied. Therefore, it was necessary to check the maximum load condition (sensible and latent) by using simulations whose results confirmed that the system is always able to guarantee temperature and relative humidity control. With regard to the COconcentration, the results confirm what has already been verified during summer operation. The value of the average concentration varies from 539 ppm (Scen. #0) to 647 ppm (Scen.# 3), with a deterioration that affects the level of the carbon dioxide index, which passes from the “good” value to the “moderate” one. Regarding PM10 and TVOC concentration, there are minimal differences similarly to what has already been observed during the summer season and indeed both indexes remain within the “good” value.

Conclusions

As expected, simulations proved that reducing the airflow rate the energy consumption would also decrease; by reducing the airflow rate by 50% the energy consumption might be reduced by 28.3% in summer operation and by 58.6% in winter operation. On the other hand, the measurement campaign showed the following results:

·         the HVAC system is able to control the indoor temperature, even under conditions of halved airflow rate;

·         in summer operation, the relative humidity was increased, due to the lesser ability of the system to dilute the water vapour linked to the decreased airflow rate, but was still acceptable (i.e., 53%);

·         in winter operation, the HVAC system was able to maintain the relative humidity within the design range by humidifying the halved external airflow rate to a lesser extent;

·         COconcentration with 50% of the nominal airflow rate resulted to be higher, but it was still within the moderate class, namely: it shifted from 539 ppm (good) to 663 ppm (moderate) in summer and from 539 ppm (good) to 647 ppm (moderate) in winter;

·         concentration of other pollutants decreases proportionally with the airflow rate.

Hence, it is clear that a decrease in the airflow rate causes a decrease in IEQ; thus, it is required to set a threshold on IEQ level, in order to control the minimum airflow rate accordingly. Precisely, the approach should focus on setting the pollutants concentration instead of setting the airflow rate in order to ensure acceptable energy performance as well as IEQ level [14]. By doing this, the airflow rate should then be evaluated based on the actual occupancy rate in the indoor environment [15]. A building automation control system able to control the HVAC system by means of real-time measures and the evaluation of an omni-comprehensive Indoor Air Quality Index (IAQI) is required to maximise such an approach [12].

References

[1]     Frontczak, M.; Wargocki, P. Literature survey on how different factors influence human comfort in indoor environments. Build. Environ.2011, 46, 922–937.

[2]     Wolkoff, P. Indoor air humidity, air quality, and health—An overview. Int. J. Hyg. Environ. Health2018, 221, 376–390.

[3]     Kang, S.; Ou, D.; Mak, C.M. The impact of indoor environmental quality on work productivity in university open-plan research offices. Build. Environ.2017, 124, 78–89.

[4]     De Santoli, L.; Garcia, D.A.; Groppi, D.; Bellia, L.; Palella, B.I.; Riccio, G.; Cuccurullo, G.; d’Ambrosio, F.R.; Stabile, L.; Dell’Isola, M.; et al. A General Approach for Retrofit of Existing Buildings Towards NZEB: The Windows Retrofit Effects on Indoor Air Quality and the Use of Low Temperature District Heating. In Proceedings of the 2018 IEEE International Conference on Environment and Electrical Engineering and 2018 IEEE Industrial and Commercial Power Systems Europe (EEEIC/I&CPS Europe), Palermo, Italy,12–15 June 2018; IEEE: Piscataway, NJ, USA, 2018; pp. 1–6.

[5]     Manfren, M.; Nastasi, B.; Piana, E.; Tronchin, L. On the link between energy performance of building and thermal comfort: An example. In Proceedings of the AIP Conference Proceedings (TMREES19), Beirut, Lebanon, 10–12 April 2019; AIP Publishing LLC: Melville, NY, USA, 2019; Volume 2123, p. 020066.

[6]     Allab, Y.; Pellegrino, M.; Guo, X.; Nefzaoui, E.; Kindinis, A. Energy and comfort assessment in educational building: Case study in a French university campus. Energy Build.2017, 143, 202–219.

[7]     Dias Pereira, L.; Neto, L.; Bernardo, H.; Gameiro da Silva, M. An integrated approach on energy consumption and indoor environmental quality performance in six Portuguese secondary schools. Energy Res. Soc. Sci.2017, 32, 23–43.

[8]     Zuhaib, S.; Manton, R.; Griffin, C.; Hajdukiewicz, M.; Keane, M.M.; Goggins, J. An Indoor Environmental Quality (IEQ) assessment of a partially-retrofitted university building. Build. Environ.2018, 139, 69–85.

[9]     Chung, M.H.; Rhee, E.K. Potential opportunities for energy conservation in existing buildings on university campus: A field survey in Korea. Energy Build.2014, 78, 176–182.

[10]   Amber, K.P.; Aslam, M.W.; Mahmood, A.; Kousar, A.; Younis, M.Y.; Akbar, B.; Chaudhary, G.Q.; Hussain, S.K. Energy Consumption Forecasting for University Sector Buildings. Energies2017, 10, 1579.

[11]   Bianco, V.; De Rosa, M.; Scarpa, F.; Tagliafico, L.A. Analysis of energy demand in residential buildings for different climates by means of dynamic simulation. Int. J. Ambient Energy2016, 37, 108–120.

[12]   Chiesa, G.; Cesari, S.; Garcia, M.; Issa, M.; Li, S. Multisensor IoT Platform for Optimising IAQ Levels in Buildings through a Smart Ventilation System. Sustainability2019, 11, 5777.

[13]   UNI Ente Italiano di Normazione Italian technical standard UNI/TS 11300-1:2014—Energy Performance of Buildings—Evaluation of Energy Need for Space Heating and Cooling. Available online: http://store.uni.com/catalogo/index.php/uni-ts-11300-1-2014.html (accessed on 18 September 2019).

[14]   Han, K.; Zhang, J.S.; Guo, B. A novel approach of integrating ventilation and air cleaning for sustainable and healthy office environments. Energy Build.2014, 76, 32–42.

[15]   Noris, F.; Delp, W.W.; Vermeer, K.; Adamkiewicz, G.; Singer, B.C.; Fisk, W.J. Protocol for maximizing energy savings and indoor environmental quality improvements when retrofitting apartments. Energy Build. 2013, 61, 378–386.