The new set of Energy Performance of building standards, developed by CEN under mandate M/480, provides a methodology to calculate overall energy performance of buildings supporting the EPBD.
| Sub-Modules | M1 Module |
| General | EN ISO 52000-1 |
| Common terms and definitions, symbols, units and subscripts | EN ISO 52000-1 |
| Applications | EN ISO 52000-1 |
| Ways to Express Energy Performance | EN ISO 52003-1 |
| Building Functions and Building Boundaries | EN ISO 52000-1 |
| Building Occupancy and Operating Conditions | EN 16798-1ISO 17772-1 |
| Aggregation of Energy Services and Energy Carriers | EN ISO 52000-1 |
| Building Zoning | EN ISO 52000-1 |
| Calculated Energy Performance | EN ISO 52000-1 |
| Measured Energy Performance | EN ISO 52000-1 |
| Ways to express Indoor Comfort | EN 16798-1ISO 17772-1 |
| External Environment Conditions | EN ISO 52010-1 |
| Economic Calculation | EN 15459-1 |
| Sub-Modules | M2 Module |
| Building Energy Needs | EN ISO 52016-1EN ISO 52017-1 |
| (Free) Indoor Conditions without Systems | EN ISO 52016-1EN ISO 52017-1 |
| Ways to Express Energy Performance | EN ISO 52018-1 |
| Heat Transfer by Transmission | EN ISO 10077-1EN ISO 10077-2EN ISO 10211EN ISO 12631EN ISO 13370EN ISO 13789EN ISO 14683EN ISO 6946 |
| Heat Transfer by Distribution & Control Infiltration and Ventilation | EN ISO 13789 |
| Internal Heat Gains | EN 16798-1ISO 17772-1 |
| Solar Heat Gains | EN ISO 52022-1EN ISO 52022-3 |
| 1 Building Dynamics (thermal mass) | EN ISO 13786 |
Energy performance of buildings — Overarching EPB assessment — Part 1: General framework and procedures
Published: 2017-06Energy performance of buildings — Overarching EPB assessment — Part 2: Explanation and justification of ISO 52000-1
Published: 2017-06 Ref. Modules: M1-1, M1-2, M1-3, M1-5, M1-7, M1-8, M1-9, M1-10Energy performance of buildings — Ventilation of buildings — Part 1: Indoor environmental input parameters for design and assessment of energy performance of buildings addressing indoor air quality, thermal environment, lighting and acoustics
Published: 2019-05Energy performance of buildings — Ventilation for buildings - Part 2: Interpretation of the requirements in EN 16798-1 — Indoor environmental input parameters for design and assessment of energy performance of buildings addressing indoor air quality, thermal environment, lighting and acoustics
Published: 2019-05 Ref. Modules: M1-6Energy performance of buildings — Indicators, requirements, ratings and certificates — Part 1: General aspects and application to the overall energy performance
Published: 2017-06Energy performance of buildings — Indicators, requirements, ratings and certificates — Part 2: Explanation and justification of ISO 52003-1
Published: 2017-06 Ref. Modules: M1-4Energy performance of buildings — Indoor environmental quality — Part 1: Indoor environmental input parameters for the design and assessment of energy performance of buildings
Published: 2017-06Energy performance of buildings — Overall Energy performance Assessment Procedures — Part 2: Guideline for using indoor environmental input parameters for the design and assessment of energy performance of buildings
Published: 2018-04 Ref. Modules: M1-6, M1-12, M2-7Energy performance of buildings — External climatic conditions — Part 1: Conversion of climatic data for energy calculations
Published: 2017-06Energy performance of buildings — External climatic conditions — Part 2: Explanation and justification of ISO 52010-1
Published: 2017-06 Ref. Modules: M1-13Energy performance of buildings — Economic evaluation procedure for energy systems in buildings — Part 1: Calculation procedures
Published: 2017-06Energy performance of buildings — Economic evaluation procedure for energy systems in buildings — Part 2: Explanation and justification of EN 15459-1
Published: 2017-07 Ref. Modules: M1-14Energy performance of buildings – Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads — Part 1: Calculation procedures
Published: 2017-06Energy performance of buildings — Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads — Part 2: Explanation and justification of ISO 52016-1 and ISO 52017-1
Published: 2017-06 Ref. Modules: M2-2, M2-3, M3–3, M4–3, M6–3, M7–3Energy performance of buildings — Sensible and latent heat loads and internal temperatures — Part 1: Generic calculation procedures
Published: 2017-06Energy performance of buildings — Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads — Part 2: Explanation and justification of ISO 52016-1 and ISO 52017-1
Published: 2017-06 Ref. Modules: M2-2, M2-3, M3–3, M4–3, M6–3, M7–3Energy performance of buildings — Indicators for partial EPB requirements related to thermal energy balance and fabric features — Part 1: Overview of options
Published: 2017-06Energy performance of buildings — Indicators for partial EPB requirements related to thermal energy balance and fabric features — Part 2: Explanation and justification of ISO 52018-1
Published: 2017-06 Ref. Modules: M2-4Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 1: General
Published: 2017-06Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 2: Numerical method for frames
Published: 2017-06Thermal bridges in building construction — Heat flows and surface temperatures — Detailed calculations
Published: 2017-06Energy performance of buildings — Hygrothermal performance of building components and building elements — Part 2: Explanation and justification
Published: 2017-07 Ref. Modules: M2-5Thermal bridges in building construction — Heat flows and surface temperatures — Detailed calculations
Published: 2017-06Energy performance of buildings — Hygrothermal performance of building components and building elements — Part 2: Explanation and justification
Published: 2017-07 Ref. Modules: M2-5Thermal performance of buildings — Heat transfer via the ground — Calculation methods
Published: 2017-06Energy performance of buildings — Hygrothermal performance of building components and building elements — Part 2: Explanation and justification
Published: 2017-07 Ref. Modules: M2-5Thermal performance of buildings — Transmission and ventilation heat transfer coefficients — Calculation method
Published: 2017-06Energy performance of buildings — Hygrothermal performance of building components and building elements — Part 2: Explanation and justification
Published: 2017-07 Ref. Modules: M2-5Thermal performance of buildings — Transmission and ventilation heat transfer coefficients — Calculation method
Published: 2017-06Energy performance of buildings — Hygrothermal performance of building components and building elements — Part 2: Explanation and justification
Published: 2017-07 Ref. Modules: M2-5Thermal bridges in building construction — Linear thermal transmittance — Simplified methods and default values
Published: 2017-06Energy performance of buildings — Hygrothermal performance of building components and building elements — Part 2: Explanation and justification
Published: 2017-07 Ref. Modules: M2-5Building components and building elements — Thermal Resistance and thermal transmittance — Calculation methods
Published: 2017-06Energy performance of buildings — Hygrothermal performance of building components and building elements — Part 2: Explanation and justification
Published: 2017-07 Ref. Modules: M2-5Thermal performance of curtain walling — Calculation of thermal transmittance
Published: 2017-06Thermal bridges in building construction — Heat flows and surface temperatures — Detailed calculations
Published: 2017-06Energy performance of buildings — Hygrothermal performance of building components and building elements — Part 2: Explanation and justification
Published: 2017-07 Ref. Modules: M2-5Energy performance of buildings — Thermal, solar and daylight properties of building components and elements — Part 1: Simplified calculation method of the solar and daylight characteristics for solar protection devices combined with glazing
Published: 2017-06Energy performance of buildings — Thermal, solar and daylight properties of building components and elements — Part 2: Explanation and justification
Published: 2017-06 Ref. Modules: M2-8Energy performance of buildings — Thermal, solar and daylight properties of building components and elements — Part 3: Detailed calculation method of the solar and daylight characteristics for solar protection devices combined with glazing
Published: 2017-06Thermal performance of building components — Dynamic thermal characteristics — Calculation methods
Published: 2017-06Energy performance of buildings — Hygrothermal performance of building components and building elements — Part 2: Explanation and justification
Published: 2017-07 Ref. Modules: M2-9Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 1: General and Energy performance expression
Published: 2017-04Heating systems and water based cooling systems in buildings — Method for calculation of system energy requirements and system efficiencies — Part 6-1: Explanation and justification of EN 15316-1
Published: 2017-04 Ref. Modules: M3-1, M3-4, M3-9, M8-1, M8-4Energy performance of buildings — Ventilation for buildings — Part 9: Calculation methods for energy requirements of cooling systems
Published: 2017-06Energy performance of buildings — Ventilation for buildings — Part 10: Interpretation of the requirements in EN 16798-9
Published: 2017-07 Ref. Modules: M4-1, M4-4, M4-9Energy performance of buildings — Ventilation for buildings — Part 3: For non-residential buildings – Performance requirements for ventilation and room-conditioning systems
Published: 2017-07Energy performance of buildings — Ventilation for buildings — Interpretation of the requirements in EN 16798-3
Published: 2017-07 Ref. Modules: M5-1, M5-4, M6-1, M6-4, M7-1, M7-4Energy performance of buildings — Energy requirements for lighting — Part 1: Specifications
Published: 2017-04Energy performance of buildings — Energy requirements for lighting. Explanation and justification of EN 15193-1
Published: 2017-04 Ref. Modules: M9Energy performance of buildings — Energy performance of buildings — Part 1: Impact of Building Automation, Controls and Building Management
Published: 2017-05Energy performance of buildings — Accompanying TR prEN 15232-1:2015
Published: 2016-09 Ref. Modules: M10-4, M10-5, M10-6, M10-7, M10-8, M10-9, M10-10Energy performance of buildings — Method for calculation of the design heat load — Part 3: Domestic hot water systems heat load and characterisation of needs
Published: 2017-07Energy performance of buildings — Method for calculation of the design heat load — Part 1: Space heating load
Published: 2017-07Energy performance of buildings — Method for calculation of the design heat load — Part 2: Explanation and justification of EN 12831-1
Published: 2017-04 Ref. Modules: M3-3Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 2: Space emission systems (heating and cooling)
Published: 2017-05Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 6-2: Explanation and justification of EN 15316-2
Published: 2017-05 Ref. Modules: M3-5, M4-5Energy performance of buildings — Part 7: Ventilation for buildings — Calculation methods for the determination of air flow rates in buildings including infiltration
Published: 2017-06Energy performance of buildings — Ventilation for buildings — Interpretation of the requirements in EN 16798-7
Published: 2017-08 Ref. Modules: M5-5Energy performance of buildings — Ventilation for buildings — Calculation methods for energy requirements of ventilation and air conditioning systems — Part 5-1 Distribution and generation — Method 1
Published: 2017-05Energy performance of buildings — Ventilation for buildings — Part 6: Interpretation of the requirements in EN 16798-5 -1 and EN 16798-5-2
Published: 2017-07 Ref. Modules: M5–6, M5–8, M6–5, M6–8, M7–5, M7–8Energy performance of buildings — Control for heating, ventilating and air conditioning applications — Part 1: Electronic individual zone control equipment
Published: 2017-05Energy performance of buildings — Control for heating, ventilating and air-conditioning applications. Accompanying TR prEN 15500-1:2015
Published: 2016-08 Ref. Modules: M3-5, M4-5, M5-5Energy performance of buildings — Ventilation for buildings — Part 5-2: Calculation methods for energy requirements of ventilation systems — Method 2: Distribution and generation
Published: 2017-08Energy performance of buildings — Ventilation for buildings — Part 6: Interpretation of the requirements in EN 16798-5 -1 and EN 16798-5-2
Published: 2017-07 Ref. Modules: M5-6, M5-8, M6-5, M6-8, M7-5, M7-8Energy performance of buildings — Controls for heating systems — Part 1: Control equipment for hot water heating systems
Published: 2017-05Controls for heating systems — Part 6: Accompanying TR prEN 12098-1:2015
Published: 2016-08 Ref. Modules: M3-5, M3-6, M3-7, M3-8Energy performance of buildings — Controls for heating systems — Part 3: Control equipment for electrical heating systems
Published: 2017-05Controls for heating systems — Part 7: Accompanying TR prEN 12098-3:2015
Published: 2016-08 Ref. Modules: M3-5, M3-6, M3-7, M3-8Energy performance of buildings — Controls for heating systems — Part 5: Start-stop schedulers for heating systems
Published: 2017-05Controls for heating systems — Part 8: Accompanying TR prEN 12098-5:2015
Published: 2016-08 Ref. Modules: M3-5, M3-6, M3-7, M3-8Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 3: Space distribution systems (DHW, heating and cooling)
Published: 2017-04Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies - Part 6-3: Explanation and justification of 15316-3
Published: 2017-04 Ref. Modules: M3-6, M4-6, M8-6Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 5: Space heating and DHW storage systems (not cooling)
Published: 2017-05Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 6-10: Explanation and justification of EN 15316-5
Published: 2017-04 Ref. Modules: M3–7, M8–7Energy performance of buildings — Ventilation for buildings — Part 15: Calculation of cooling systems
Published: 2017-06Energy performance of buildings — Ventilation for buildings — Part 16: Interpretation of the requirements in EN 16798-15
Published: 2017-06 Ref. Modules: M4-7Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 4-3: Heat generation systems, thermal solar and photovoltaic systems
Published: 2017-05Energy performance of buildings — Method for calculation of system energy performance and system efficiencies — Part 6-6: Explanation and justification of EN 15316-4-3
Published: 2017-04 Ref. Modules: M3–8, M8-7, M8-8, M11–8Energy performance of buildings — Ventilation for buildings — Part 13: Calculation of cooling systems
Published: 2017-06Energy performance of buildings — Ventilation for buildings — Part 14: Interpretation of the requirements in EN 16798-13
Published: 2017-06 Ref. Modules: M4-8Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 4-1: Space heating and DHW generation systems
Published: 2017-05Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies - Part 6-4: Explanation and justification of EN 15316-4-1
Published: 2017-04 Ref. Modules: M3-7, M8-7Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 4-2: Space heating generation systems, heat pump systems
Published: 2017-04Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 6-5: Explanation and justification of EN 15316-4-2
Published: 2017-04 Ref. Modules: M3-8, M8-8Energy performance of buildings – Method for calculation of system energy requirements and system efficiencies – Part 4–4: Heat generation systems, building-integrated cogeneration systems
Published: 2017-04Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 6-7: Explanation and justification of EN 15316-4-4
Published: 2017-04 Ref. Modules: M3-8, M8-8, M11–8Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 4-5: District heating and cooling
Published: 2017-05Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 6-8: Explanation and justification of EN 15316-4-5
Published: 2017-04 Ref. Modules: M3-8, M4-8, M8-8, M11-8Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 4–10: Wind power generation systems
Published: 2017-05Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 4-8: Space heating generation systems, air heating and overhead radiant heating systems, including stoves (local)
Published: 2017-04Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 6-9: Explanation and justification of EN 15316-4-8
Published: 2017-05 Ref. Modules: M3-8, M8-8, M11-8Energy performance of buildings — Heating and DHW systems in buildings — Part 3: Measured energy performance
Published: 2017-04Energy performance of buildings — Measured energy performance — Part 4: Explanation and justification of EN 15378-3
Published: 2017-05 Ref. Modules: M3-10, M8-10Energy performance of buildings — Heating systems and DHW in buildings — Part 1: Inspection of boilers, heating systems and DHW
Published: 2017-05Energy Performance Of Buildings — Heating Systems And Dhw In Buildings — Part 2: Explanation and justification of EN 15378-1
Published: 2017-04 Ref. Modules: M3-11, M8-11Energy performance of buildings — Ventilation for buildings — Part 17: Guidelines for inspection of ventilation and air conditioning systems
Published: 2017-06Energy performance of buildings — Ventilation for buildings — Interpretation of the requirements in EN 16798-17
Published: 2017-06 Ref. Modules: M4-11, M5-11, M6-11, M7-11Energy performance of buildings — Inspection of Automation, Controls and Technical Building Management — Part 1
Published: 2017-07Inspection of Building Automation, Controls and Technical Building Management — Part 2: Accompanying prEN 16946-1:2015
Published: 2016-09 Ref. Modules: M10-11Energy performance of buildings — Building Management System — Part 1
Published: 2017-06Building Management System — Part 2: Accompanying prEN 16947-1:2015