The
European Directive on the Energy Performance of Buildings (EPBD) [1] requires
that Member States set up a calculation of the energy performance (article 3)
and a certification (article 11), with an Energy Performance Certificate (EPC)
(article 12) showing to the owner or tenant the energy performance of his or
her building compared to reference values. Member States must also establish an
independent control system for the energy performance certificates (article
18), including a check of the results stated and of the input data used.
According to article 27, non-compliance must be sanctioned.
These
energy performance calculations resulting in EPCs
need input data describing the building (location, climate, orientation, area,
construction products used and their implementation) and its systems (HVAC,
lighting, solar shading, local production of electricity…). In order to get a correct
assessment of the energy performance, it is necessary that:
·
the
input data for the energy performance calculation are compliant and an evidence
of this compliance exists;
·
these input data are easily accessible to experts in
charge of the calculations.
This
article describes examples of existing approaches in European countries that
help for compliant and/or easily accessible EPC input data for HVAC systems.
These examples are taken from a report [2] of the European project QUALICHeCK, co-funded by the Intelligent Energy Europe Programme of the European Union.
In QUALICHeCK, the following definitions are applied:
1. A quantity used as an input data for the
calculation or the assessment of the energy performance of a building, and/or
the declaration of its energy performance in the Energy Performance Certificate
(EPC), is compliant if this data has been established in line with the
procedures in force in the context of the applicable legislation.
2. It is easily accessible if it
is able to be found, seen and used by taking reasonable time, effort or money.
The
procedures to obtain compliant data should be publicly available and may be
integrated into regulations, codes, standards, professional rules,...
The
evidence that the data have been obtained according to these procedures may
rely on:
·
the
control by an independent third-party;
·
the
declaration by the manufacturer;
·
the
proven competence of the expert in charge of assessing the data;
·
...
Note that
compliant does not necessarily mean accurate. The procedure to get a data may
introduce an error, but if this procedure is recognised,
the data will be compliant. Therefore, compliant data may be far from real
values. For example, a default value used as an input data according to the
procedures may be too pessimistic or too optimistic compared to the real value.
Nevertheless, it will meet the definition of compliant data.
Considering
that an information can be found and used by taking
reasonable time, effort and money is subjective. It has to be appreciated in
the context of the best available information technologies. In Europe, a data
will be considered as easily accessible if it can be found with quite the same
time, effort and money as an information that would be
available for free on an Internet page.
One of the
identified examples described in report of the European project QUALICHeCK [2] contributes to easily accessible data.
A voluntary
scheme has been implemented in France by the ventilation system manufacturers
under the umbrella of their national association, Uniclima,
with the technical support of CETIAT, in order to publish harmonized data.
Requirements
have been defined about the characteristics to be published in the manufacturer
documentations (technical sheet, website, catalogue, and packaging) for 19
different ventilation and air handling products, together with the conditions
for obtaining and displaying them (standards to be used, quantities and units
to be published).
Data
published according to this scheme are identified by a specific logo. Joining
the scheme is free. The development and update is operated by manufacturers
within Uniclima.
The scheme
allows professionals to easily find data that are published in a harmonised way, compatible with their use for the EPC
calculation.

Figure 1.
Logo to identify data published according to the scheme.
This
approach is described in more details in a dedicated QUALICHeCK
factsheet [3].
One of the
identified examples contributes to compliant data.
In order to
reduce the variability in the values of building airtightness
between testers and to improve the consistency between test results and EPC
input data, several countries (the Czech Republic, Denmark, France, Germany,
Ireland, Sweden, the United Kingdom) have implemented schemes to qualify
testers.
Such
schemes reduce the risk of wrong values due to unintentional mistakes (caused
by lack of competence) and lead to more reliable test results,
that are used as input data for the EPC calculation.
This approach is described in details in a dedicated article of the same issue of REHVA Journal ([4]).
Some of the
identified examples provide interesting approaches to achieve compliant and easily
accessible data.
Product
characteristics databases have been implemented in Belgium, the United Kingdom
and France.
They
provide data related to products that are useful for the EPC calculation, with
an easy access, through an online public website.
In
addition, the data are compliant together with an evidence of their compliance
as they are controlled by a third-party (Belgium, France), or because the
manufacturer must provide the data with validated evidence of their performance
(UK).
The Belgian
EPBD product database gives the characteristics of hundreds of ventilation and
thermal insulation products, as well as sunscreens. It is managed by BBRI on
behalf of the three Regions of Belgium.

Figure 2. Belgian EPBD product database (http://www.epbd.be) - Web page (in French) showing the list of products covered: insulation products, opaque construction products, sunscreens, ventilation components/systems.
The database implemented in the United Kingdom covers heating systems, ventilation systems and heat recovery systems. It is managed by BRE on behalf of the Department of Energy & Climate Change.

Figure 3. Product database in the UK (http://www.ncm-pcdb.org.uk/sap) – Part of the web page showing the list of products covered.
The French database is focused on heating systems (boilers, heat pumps, solar thermal systems, domestic hot water systems, hot water radiators, independent gas-fired space heaters). It has been launched by Uniclima (French association of heating system manufacturers) and is managed by the French association ATITA.

Figure 4.
French product database (http://www.rt2012-chauffage.com) - Web page showing
the list of products covered.
The use of these databases by product manufacturers is voluntary. The cost of their operation is paid by manufacturers who decide to join. The success of such databases is rather high, with possible or actual connections to the software used to calculate the building energy performance.
A possible
way to generate compliant and accessible EPC input data for innovative products
is illustrated by one of the identified examples. A scheme implemented in
Belgium allows assessing the performance of innovative products thanks to
specific procedures, defined by a collective of relevant industrial
associations, assisted by experts and with representatives of the Regions. To a
certain extent, similar schemes (but with some substantial differences) exist
in France and The Netherlands.
The Belgian
example is implemented in the framework of the Belgian technical body for the
approval of construction products. The manufacturers may use this scheme on a
voluntary basis and pay for the corresponding costs.
The scheme
has so far mainly been used for innovative ventilation products, and especially
for demand-controlled residential ventilation systems, for which the procedure
consists in the calculation of a performance coefficient from the
characteristics of the product. This performance coefficient is then used as an
input data into the building energy performance calculation.
The scheme
provides compliant input data with an evidence of compliance, as the product
characteristics are checked by a third-party and the correct implementation of
the assessment procedure is checked by the approval body.
The data to
be used for the EPC calculation are easily accessible as they are published on
the regional public authorities’ websites.
In order to
make the access to the EPC input data easier, the approach may be to set up
rules for a harmonized publication of product performance (example in France).
In order to
improve the compliance and evidence of compliance of EPC input data, the
approach may be to implement a qualification scheme, as e.g. for building airtightness testers in the Czech Republic, Denmark,
France, Germany, Ireland, Sweden and the United Kingdom, thus securing the test
result used as an input data for the EPC calculation.
In order to
improve the compliance and evidence of compliance of the EPC input data and the easy
access to them, the approach may be:
·
to
establish a database of product characteristics (examples in Belgium, France
and the United Kingdom), combined with either a control by a third party, or a
validated performance of the published values;
·
to set up a procedure for generating compliant
EPC input data for innovative products (example in Belgium).
These
approaches often have a high potential for replication in other countries.
Their potential of extension to other products is also often high.
All the
approaches that provide compliant data contribute to a more accurate
calculation of the energy performance and thus reduce the risk for
non-compliance of the actual building energy performance with the minimum
requirements of the regulations.
[1] Directive 2010/31/EU of the European
Parliament and of the Council of 19 May 2010 on the energy performance of
buildings (recast) - Official Journal of the European Union – 18 June 2010 –
pp. L153/13 to L153/35.
[2] How to get compliant and accessible data for
the energy rating calculation of a building? - Overview of some existing
approaches, François Durier and al., October 2014, http://qualicheck-platform.eu/results/reports/
[3] French voluntary scheme for harmonized
publication of ventilation product data, François Durier,
Laure Mouradian, FabriceLamarre, April 2015, http://qualicheck-platform.eu/results/factsheets/
[4] Competent tester schemes for building airtightness, ValérieLeprince, François RémiCarrié, pp. 16-17, REHVA Journal N°4, August 2015.
![]()
QUALICHeCK responds to the challenges related to compliance of
Energy Performance Certificate (EPC) declarations and the quality of the
building works. Find out more at http://qualicheck-platform.eu.
The
QUALICHeCK project is co-funded by the Intelligent
Energy Europe Programme of the European Union. The sole responsibility for the
content of this article lies with the author(s). It does not necessarily
reflect the opinion of the European Union. Neither the EASME nor the European
Commission are responsible for any use that may be
made of the information contained therein.