8.01 Energy recovery in air conditioning systems By: ATECYR

This guidebook shows the different technologies for energy recovery in air conditioning systems. By increasing the energy needs of society, it is important to apply alternatives like heat recovery to meet the needs with the lowest economic and environmental cost.

  • Energy generation and recovery systems
  • Energy
  • Recovery
  • HVAC

8.03 Thermal solar Installations for the production of sanitary hot water By: ATECYR

The guidebook describes the technologies applied for the production of Sanitary Hot Water in tertiary buildings as well as the methodology of design and dimensioning of the facilities. The main concepts used for solar thermal installations for the production of DHW are also described in detail.

  • Energy generation and recovery systems
  • Renewable energy
  • HWS
  • solar

8.04 Solar thermal energy. Practical cases By: ATECYR

This guidebook describes in a practical way the design and dimensioning of solar thermal installations. The design criteria of the different components that make up the solar thermal installation are analyzed

  • Energy generation and recovery systems
  • Renewable energy
  • HWS
  • Solar
  • Success cases

9.01 System types By: ATECYR

The guidebook details the most used HVAC systems in the most complex installations. The most important aspect when it choosing a system is perhaps the fit between the system and the type of application

  • Systems design
  • Type
  • HVAC

9.02 Relationship between the building and the air conditioning system By: ATECYR

It aims to facilitate the work of the technician when choosing an air conditioning system suitable for a particular project. The first part deals with the most important constraints of the project (architectural, urban, system) and the second gives examples of typical installations

  • Building performance management
  • HVAC
  • thermal demand
  • energy generation

9.04 Radiant floor systems By: ATECYR

To generate heating, one of the most commonly used systems is underfloor heating. This guide explains the design and sizing of these systems that can be used both for heating and cooling

  • Heating and cooling systems
  • HVAC
  • Radiation
  • Hot

9.05 Air conditioning systems By: ATECYR

The guidebook refers to select the terminal units in active air conditioning systems that are additional elements to the building itself and entail energy consumption

  • Systems design
  • HVAC
  • Description

9.06 Selection of secondary equipment according to the system By: ATECYR

It is a guide designed with a double purpose, to guide the student and for the engineer who starts in the development of air conditioning projects. It can also be taken as an element of quality control in the writing of projects

  • Systems design
  • HVAC
  • Types
  • Terminal units