By type

By topic

Legionellosis Prevention in Building, Water and HVAC Systems: A Practical Guide for Design, Operation and Maintenance to Minimize the Risk (GB18) By: REHVA

This Guidebook is a practical guide for design, operation and maintenance to minimize the risk of legionellosis in building water and HVAC systems.

  • Heating and cooling systems
  • Ventilation systems
  • Water supply and sanitary systems
  • air conditioning
  • domestic hot water
  • evaporative cooling tower

Mixing ventilation - Guidebook on Mixing Air Distribution Design (GB19) By: REHVA

In this guidebook most of the known and used in practice methods for achieving mixing air distribution are discussed. Mixing ventilation has been applied to many different spaces providing fresh air and thermal comfort to the occupants.

  • Ventilation systems
  • Indoor environmental quality and building users
  • mixing ventilation
  • thermal comfort
  • mixing air distribution design

Advanced System Design and Operation of GEOTABS Buildings (GB20) By: REHVA

This guidebook provides comprehensive information on GEOTABS systems. It is intended to support building owners, architects and engineers in an early design stage showing how GEOTABS can be integrated into their building concepts.

  • Heating and cooling systems
  • Systems design
  • GEOTABS systems
  • energy efficiency of TABS
  • heating and cooling

Active and Passive Beam Application design Guide (GB21) By: REHVA

Active and Passive Beam Application Design Guide provide energy-efficient methods of cooling, heating, and ventilating indoor areas, especially spaces that require individual zone control and where internal moisture loads are moderate.

  • Heating and cooling systems
  • Ventilation systems
  • active and passive beams
  • energy efficiency
  • space cooling
  • heating and ventilation

Introduction to Building Automation Controls and Technical Building Management (GB22) By: REHVA

This guidebook aims to provide an overview on the different aspects of building automation, controls and technical building management.

  • Systems design
  • Building performance management
  • Building automation, controls and technical building management systems
  • building automation
  • controls
  • technical building management

Displacement Ventilation (GB23) By: REHVA

The aim of this Guidebook is to give the state of the art knowledge of the displacement ventilation technology, and to simplify and improve the practical design procedure.

  • Ventilation systems
  • Systems design
  • displacement ventilation systems
  • design procedure

Fire Safety in Buildings - Smoke Management Guidelines (GB24) By: REHVA

This guidebook describes the different principles of smoke prevention and their practical implementation by way of natural and mechanical smoke extraction systems, smoke control by pressurization systems and appropriate partition measures.

  • Fire safety systems
  • Ventilation systems
  • Systems design
  • smoke prevention
  • mechanical smoke extraction systems
  • partition measures

Residential Heat Recovery Ventilation (GB25) By: REHVA

  • Ventilation systems
  • Systems design
  • Building performance management
  • ventilation system performance
  • calculations
  • heat recovery