Reset filters

By type

By topic

5.01 Duct calculation By: ATECYR

It aims to guide on how to perform the dimensioning of the network of conduits, recommended to consult the documentation provided by the manufacturers of diffusers on the selection of the same, function of the specific design of each of the real equipment of the market

  • Ventilation systems
  • Design
  • Conduits
  • Leak of charges

6.01 Combustion By: ATECYR

This guidebook gathers the basic concepts about combustion, its theory, and its practice in air conditioning installations

  • Energy generation and recovery systems
  • Theory
  • Combustion

7.01 Calculation of load and thermal demand By: ATECYR

These guidebook indicates the relationship of the behavior of the building to the variations of external conditions and its thermal demand to reach the thermal well-being design conditions

  • Heating and cooling systems
  • Thermal demand
  • Building
  • Design

7.03 Data entry to the LIDER and Calener VyP programs (Spanish official program to certify) By: ATECYR

This document was created to help users of the LIDER and CALENER VyP programs in their work to verify compliance with the CTE-HE1 and in the Energy Certification of new buildings, regulated under Royal Decree 47/2007

  • Building performance calculation and simulation
  • Cetification
  • Simulation program
  • LIDER

7.04 Data entry to the CALENER GT program (Spanish official program to certify) By: ATECYR

This guidebook helps potential users of CALENER GT program on their work of certification of tertiary buildings

  • Building performance calculation and simulation
  • Cetification
  • Simulation program
  • Calener GR
  • DOE 2.2

7.05 Calculation of thermal loads By: ATECYR

This document specifies how to calculate the building thermal loads. It uses the calculation methodology of the "Temporary Radiant Series Method" recommended by ASHRAE for the calculation of loads. The calculation is accurate for both summer and winter conditions to maintain user specified internal conditions.

  • Building performance calculation and simulation
  • Calculation
  • Thermal loads
  • Design

7.06 Simplified procedures for the certification of new dwellings(Spanish official program to certify) By: ATECYR

In this guidebook, the different methods to certify new residential buildings are analyzed. These methods use a simplified calculation for both energy demand and energy consumption. It identifies the methods employed by the programs: Ce1, Ce2, CES and CERMA, whose procedures and characteristics are described

  • Building performance calculation and simulation
  • Cetification
  • Simplified simulation program

7.07 BIM Methodology in Air Conditioning By: ATECYR

The BIM methodology allows to optimize resources and costs dedicated to the elaboration and execution of building projects. This guidebook shows from different points of view, the challenges founded on this new technology which will be an opportunity to generate added value in building projects.

  • Building performance calculation and simulation
  • Simulation program
  • HVAC
  • BIM

Discover other topics

Stay Informed

Follow us on social media accounts to stay up to date with REHVA actualities

0

0 product in cart.products in cart.